Technical Data
|
GW10KL-ET
|
|
Battery Type
|
Li-Ion
|
|
Nominal Battery Voltage (V)
|
500
|
|
Battery Voltage Range (V)
|
180~600
|
|
Max. Continuous Charging Current (A)
|
25
|
|
Max. Continuous Discharging Current (A)
|
25
|
|
Max. Charge Power (W)
|
10,000
|
|
Max. Discharge Power (W)
|
10,000
|
|
Max. Solar Input Power (W)
|
13,300
|
|
Max. Solar Input Voltage (V)*1
|
1000
|
|
Solar MPPT Operating Voltage Range (V)*2
|
200~850
|
|
Solar MPPT Voltage Range at Nominal Power (V)*3
|
320~850
|
|
Start-up Solar Panel Voltage (V)
|
180
|
|
Nominal Solar Input Panel Voltage (V)
|
620
|
|
Max. Input Current per MPPT (A)
|
12.5/22
|
|
Max. Short Circuit Current per MPPT (A)
|
15.2/27.6
|
|
Max. Backfeed Current to The Array (A)
|
0
|
|
Number of MPP Trackers
|
2
|
|
Number of Strings per MPPT
|
1/2
|
|
Nominal Apparent Power Output to Utility Grid (VA)
|
10,000
|
|
Max. Apparent Power Output to Utility Grid (VA)*2*4
|
11,000
|
|
Nominal Apparent Power from Utility Grid (VA)
|
15,000
|
|
Max. Apparent Power from Utility Grid (VA)
|
15,000
|
|
Nominal Output Voltage (V)
|
400/380,
3L/N/PE
|
|
Output Voltage Range (V)
|
0~300
|
|
Nominal AC Grid Frequency (Hz)
|
50/60
|
|
AC Grid Frequency Range (Hz)
|
45~65
|
|
Max. AC Current Output to Utility Grid (A)
|
16.5
|
|
Max. AC Current From Utility Grid (A)
|
22.7
|
|
Max. Output Fault Current (Peak and Duration) (A)”
|
45@2μs
|
|
Inrush Current (Peak and Duration) (A)
|
45@2μs
|
|
Nominal Output Current (A)
|
14.5
|
|
Power Factor
|
|
|
Max. Total Harmonic Distortion
|
<3%
|
|
Maximum Output Overcurrent Protection (A)
|
45
|
|
Back-up Nominal Apparent Power (VA)
|
10,000
|
|
Max. Output Apparent Power (VA)*3
|
10,000 (16,500@60
sec)
|
|
Nominal Output Current (A)
|
14.5
|
|
Max. Output Current (A)
|
16.5
|
|
Max. Output Fault Current (Peak and Duration) (A)
|
45@2μs
|
|
Inrush Current (Peak and Duration) (A)
|
45@2μs
|
|
Maximum Output Overcurrent Protection (A)
|
45
|
|
Nominal Output Voltage (V)
|
400/380
|
|
Nominal Output Frequency (Hz)
|
50/60
|
|
Output THDv (@Linear Load)
|
<3%
|
|
Max. Efficiency
|
97.60%
|
|
European Efficiency
|
96.80%
|
|
Max. Battery to AC Efficiency
|
97.50%
|
|
MPPT Efficiency
|
99.90%
|
|
PV Insulation Resistance Detection
|
Integrated
|
|
Residual Current Monitoring
|
Integrated
|
|
PV Reverse Polarity Protection
|
Integrated
|
|
Anti-islanding Protection
|
Integrated
|
|
AC Overcurrent Protection
|
Integrated
|
|
AC Short Circuit Protection
|
Integrated
|
|
AC Overvoltage Protection
|
Integrated
|
|
DC Switch
|
Optional
|
|
DC Surge Protection
|
Type III
|
|
AC Surge Protection
|
Type III
|
|
Remote Shutdown
|
Integrated
|
|
Operating Temperature Range (℃)
|
-35~+60
|
|
Relative Humidity
|
0~95%
|
|
Max. Operating Altitude (m)
|
4000
|
|
Cooling Method
|
|
|
User Interface
|
LED, APP
|
|
Communication with BMS*6
|
RS485, CAN
|
|
Communication with Meter
|
RS485
|
|
Communication with Portal
|
|
|
Weight (kg)
|
25
|
|
Dimension (W×H×D mm)
|
|
|
Noise Emission (dB)
|
<30
|
|
Topology
|
Non- isolated
|
|
Self-consumption at Night (W) – no backup power
|
<15
|
|
Ingress Protection Rating
|
IP66
|
|
DC Connector
|
|