Features
- Two Versions:Â Bluetooth for non-CANbus Systems and CANbus for Victron GX Control systems
- Bluetooth Version has full display of SOC, Voltage and Time to Go as well as diagnostics.
- CANbus control means no active shunts for easier plug-n-play installation
- Compatible with Victron GX: Venus, Cerbo, Touch 50 Display
- Compatible with Safiery Canbus alternator controller
- Designed specifically so that 2 batteries as a perfect pair accept 250A of charge from Landcruiser 250A Alternators. 400Ah will be repenished in less than 2 hours.
- Slimline 125mm wide suits compact installations
- 3 year warranty
Safiery 200Ah CANbus Lithium Product Specification
No. |
Item |
Particulars |
Remark |
1.     |
Li-ion Cylindrical Cell |
32700Â Â 3.2V Typical:6Ah |
132PCS (4S33P) |
2.     |
BMS |
Active Automatic cell balancing |
Bluetooth BMS Safiery App |
3.     |
Communication |
Bluetooth to Safiery App OR CANbus to Victron BMS-Can Protocol |
Bluetooth OR RJ45 Connector |
4.     |
Dimensions |
L: 512mm W: 125mm H: 325mm |
|
5.     |
Multiple Batteries |
Up to 4 in parallel for 800Ah |
Positive in Battery 1 Negative out Battery 4 |
6.     |
Rated Capacity |
At least 200Ah at 12.8V |
C5 Rating |
7.     |
Nominal Voltage |
12.8V |
|
8.     |
Voltage at end of Discharge |
10.2V |
|
9.     |
Charging Voltage |
14.5V±0.1V |
Standard AGM Charge of 14.4V |
10.  |
Charge Protection Voltage |
3.75V±0.1V per cell = 15V |
Single Section Protection Voltage |
11.  |
Discharge Protection voltage |
2.5V±0.1V per cell = 10V |
Single Section Protection Voltage |
12.  |
Internal Impedance |
≤9mΩ |
|
13.  |
Standard Charge |
CCÂ 0.5Â CV 14.4V to 14.6V |
|
14.  |
Maximum Charge Current |
140AÂ |
|
15.  |
Maximum Continuous Discharge Current |
200A |
|
16.  |
Operation Temperature Range |
Charge: 0~45℃ Discharge: -30~80℃ |
|
17.  |
Storage Temperature Range |
0~40℃ |
|
18.  |
Case |
Black Metal with M8 terminal |
|
19.  |
Storage Humidity Range |
60±25%RH. |
|